- Allows operator to push, turn or pull. Coupling is locked with a pin.
- Out of stockTEMPORARILY OUT OF STOCK Cherne Smoke Generating Devices (SGD), or “smoke bombs”, produce a thick, dense smoke that is highly effective for performing smoke tests. Smoke generating devices are time proven, simple to use, and can be used by themselves or with most smoke blowers on the market today. Features:
- Produces a thick, dense smoke
- Time-proven
- Simple to use
- Can be used with most smoke blowers
- 3 minute bombs available with a double wick that allows units to be strung together for a longer smoke time
- Method for the Sectional Renovation of Lateral Junctions and Pipes in the Main Sewer Line Main pipe: DN 130 to DN 600 Lateral pipe: DN 100, 125, 150 and 200 at 30° to 90° The DrainLCR-S system is used to repair and permanently seal main/lateral interfaces and connections up to 500 mm from the mainline down into the lateral. The system can use either an LCR-S hat profile or an LCR-S liner. The main-to-lateral interface in the main pipe is sealed only by the rim of the LCR-S hat profile, while the LCR-S liner in the main pipe is designed as a short liner. Benefits:
- Reliable to install: 1. Inversion is not possible until positive engagement of the pathfinder. 2. The signal will not sound until complete inversion.
- Technical advance: Only the inversion process allows pipe bends and offset joints to be relined.
- Meets practical needs: Successful repairs are possible with little equipment needs only, even in the presence of groundwater.
- Price advantage: Low investment cost, because you need to buy just the packers actually required.
- Practical: The low-weight mobile unit with low space requirements can be placed even in a small car.
- Flexible: It is also possible to use air push rods or a carriage.
- Accessibility: The LCR packers can be folded as required inside the manhole.
- User-friendly equipment: The LCR packers can be converted to other sizes as required.
- Used for assembly and disassembly of the rod couplings and nuts. The end of the handle is designed to fit the center hole of the coupling. 2 are recommended.
- Hydrostatic Test Pumps are designed for pressure testing water lines and sewer force mains as prescribed by AWWA Standard C600 Installation of Ductile-Iron Water Mains and C605 Installation of PVC Pressure Pipe. Aqua-Loc® Hydrostatic Test Pumps are designed to be the most user friendly in the industry. Both Diaphragm and Piston Style pumps are available and come powered by either a Honda or Briggs & Stratton engine. Aqua-Loc® Hydrostatic Test Pump: Diaphragm Style – Features:
- Honda or Briggs Engine with low oil shut off
- Hypro® Twin diaphragm pump - 9.5 gpm/550 PSI
- Handles up to 10% chlorine solutions
- May be run dry
- Test pressures can be set from 100-550 psi
- Integral manifolds - eliminates leak points
- Enclosed gear reduction - excellent heat dissipation
- Pulsation dampener - no need to surge tank
- Heavy-duty frame
- Hydraulic quick-disconnect - brass, swivel fitting
- Inline strainer - easy to clean clear bowl
- Clear hose - flow verification
- Silicone filled test gauge w/stainless steel case
- A lightweight aluminum pole system which is used to place the Remo® plug in the sewer system. For longer then 1.8m use two poles with the Remo® Pole Adapter.
- Universal model with rectangular base ideal for lifting, moving and repositioning the majority of covers and grilles in cast iron and ferrous materials. The handle is telescopic and folding, minimising the space needed. The exclusive configuration gives versatility of use in four ways to fit the majority of lifting/repositioning operations. The plate, with 16 powerful neodymium magnets assures a lifting force of 300kg with a weight of only 7kg.
- Designed to penetrate the toughest blockages the enz® pointed nozzle directs 30% of your jetters flow forward 15º through its hardened tip to break up and open the blockage. The remainder is exhausted at a 20º angle to provide positive thrust and penetrating power. Ideal for roots, silt, heavily blocked pipes and frozen pipes. L= Litres per minute R= Number of Rear Facing Jets F= Number of Front Facing Jets If a nozzle you require is not listed please call or enquire online for price & availability.
- Out of stockDesigned to penetrate the toughest blockages the enz® pointed nozzle directs 30% of your jetters flow forward 15º through its hardened tip to break up and open the blockage. The remainder is exhausted at a 20º angle to provide positive thrust and penetrating power. Ideal for roots, silt, heavily blocked pipes and frozen pipes. L= Litres per minute R= Number of Rear Facing Jets F= Number of Front Facing Jets If a nozzle you require is not listed please call or enquire online for price & availability.
- Our new Super Heavy Duty Puma Tail hose guide is molded from a smooth bore rubber hose that holds up to abuse. These Puma Tails last longer to keep your workers on the job and avoid costly sewer hose damage. The cuffed ends are steel banded and silicone sealed. The attached 25ft. rope is attached with a super strong King Clamp with a rubber gasket around the guide. Sizes available: 2" Heavy Duty Tiger Tail Puma Hose Guide & 3" Heavy Duty Tiger Tail Puma Hose Guide Please contact us for price & availability.
- 45KGS Capacity. An overall metal retriever. Connects right to our fiberglass poles. Great tool for retrieving that lost tool; can lift valve covers. Comes with steel protective plate to protect magnet. Zinc plated.
A perfect start into "No-Dig" business
You always need high-quality equipment to obtain high-quality results. The equipment tailored to the needs of the Trelleborg ShortLiner system offers all that is necessary to achieve high-quality results. The Trelleborg ShortLiner Patch Kit simplifies your work. Available in various configurations, it’s ready to tackle single repairs in pipes ranging from 100 mm to 375 mm in diameter and repair lengths from 0.6 meters to 1.5 meters.- Resin systems for full rehabilitation and sectional renovation of pipes and sewers. Trelleborg Pipe Seals manufactures high-quality resin systems for the rehabilitation of sewers and wastewater pipes. Three basic resin types are available:
- EpoxyResins for CIPP lining applications; and
- SilicateResins for lateral connection repairs and patches. Available in fast WOI, Winter and Summer.
Trelleborg Resin Systems
Two-component resin mixture made of component A (synthetic resin) and B (hardener) Trelleborg EPROPOX resins are used in the Trelleborg DrainLiner methods (CIPP liners) as well as in the Trelleborg DrainLCR methods. To be able to meet the varied needs of our installers, we developed a multitude of epoxy resin systems geared to specific applications. These systems stand out for their improved mechanical properties, e.g. flexural modulus, flexural stress, TG and reduction factor, which are considerably higher than those found in conventional resin systems. Thanks to their viscosity and surface tension, all EpoxyResin systems are extremely easy to handle, penetrate carrier materials quickly and provide very good mechanical properties and chemical strengths after final cure. Both filled and unfilled resin systems are available, depending on the particular application.Silicate Resin Systems
These resin systems are used especially for lateral connection and short repairs (DrainLCR and DrainPacker). They are easy to handle and quick to install and stand out for their good mechanical properties and chemical resistance after final cure. The patented two-component resin mixture is made up of the components B (resin) and A (hardener) at a mixing ratio of 2:1 (by volume). Benefits:- Cures at ambient temperature within about 1 to 3 hours (cure times can be controlled and adjusted)
- Excellent performance both at extremely high and at extremely low temperatures
- Very good resistance to acids and caustics (pH 1 - 13.5) after final cure
- High temperature resistance of short/CIPP liner after final cure
- No volatile organic compounds (styrene free)
- Excellent adhesion to many pipe materials like vitrified clay, plastic, steel etc. with a close frictional and positive fit to HDPE pipes
- Virtually no shrinkage (<0.6%)
- Can be used at a wide range of ambient temperatures
- Excellent performance both at extremely high and at extremely low temperatures
- Expected service life of more than 50 years as proven by 10,000-hour test
- The cured resin is self-extinguishing and can thus be used in critical areas such as airports and tunnels
- Tested by independent bodies (IKT - Gelsenkirchen, WRc UK)
- In compliance with international standards such as DIBt, ASTM, WIS and DIN EN
- Out of stockAPS90 is a multi-purpose, wheeled, folding lever designed for use in combination with the CL10, CL11, PM500, Mechanical Clamps and BT95 Lifting Bar. The lever guarantees fast, easy and safe operations in lifting, moving and repositioning manhole covers for underground water, sewerage, gas and telecommunications networks. The tool is "operator friendly" as these manoeuvres can be performed safely by pushing down rather than lifting. This means the spine is released and not compressed, eliminating potential back injuries.
- Out of stock‘Fog-smoker’ is a compact but powerful unit with integrated fan. This unit is especially suited for professional inspection of tubes, sewers, and tanks to locate leaks and wrong connections. 10 different air and fog volumes can be selected at the control panel (soft keyboard). The fog fluid creates a dense white fog, but no health hazard.Technical data:Please contact us for price & availability.
- Dimensions (L x W x H) : 560 x 295 x 350mm
- Weight (incl. 5 l fluid) : 21.5kg
- Max. power consumption : 2,400 Watt (230 or 110V)
- Fluid consumption : with max. output : 120 ml/min
- With permanent operation : 35 ml /min
- Air output: about - 3,000 lpms
- Plastic hose DN 50mm with “Storz C” coupling and guiding tube.
- 5 litres fogging fluid in a container
- Rugged transport case
- Made of wear resistant hardened steel, the enz® Grenade bomb has been designed with jets set at both 10º & 30º and a heavy weight for its size. These factors allow the nozzle to travel in the lower half of the pipe. The nozzle provides a strong traction and effective removal of loose rubble, sand, stone and soft deposits. This nozzle can also be used for pre-cleaning before the use of an enz® Chain Flail head or Rootcutter. If a size you require is not listed please call or enquire online for price & availability.
- Out of stockBlack steel shovels comes in various shapes. Connects to fibreglass poles.
- Smoke/Fogger fluid that produce thick, dense smoke to effectively perform smoke tests. Two types of smoke/fogger fluid Available
- 20L Petroleum based smoke fluid - Suits petrol smoke blower
- 25L Glycols and water based fogger fluid - Suits electric smoke blower
- Out of stockTiger Tail (aliminium) 5 Roller Guide with 7.6M (25') Rope . Lowers your hose and nozzles into sewer pipe. Protects hose, lightweight and easy to use. 5 polyurethane rollers.
- Prevents infiltration between Liner and Host Pipe. The Drain Liner End Seal utilizes the patented Slotted Band® to provide maximum sealing force with a minimum reduction in pipe diameter. This unique design captures the rubber and compresses it against the host pipe and new CIPP liner creating a permanent mechanical seal. The patented Slotted Band is constructed from a single piece of Stainless Steel (EN 1.4307) precisely rolled to match the diameter of the CIPP liner. The unique shape of the Slotted Band provides the maximum amount of strength and sealing force with the least possible thickness. The band is then expanded using a hydraulic expansion tool. As the band expands the integral latching mechanism progresses from slot to slot, positively locking on each one until the next one is reached. There is an audible click created by the spring/rubber interaction as the band is expanded into place. Benefits
- Manufactured from EPDM Rubber and Stainless Steel to withstand the harsh sanitary sewer environment.
- Complies with material property requirements of ASTM C923
- Quick and easy to install