• The Model 325 Gasoline powered sewer cleaner is designed to clean 100mm to 355mm diameter lines for distances up to 152M and is ideal for industrial, contractor, and municipal use.
  • One of the major benefits of mechanical plugs over pneumatic plugs is mechanical plugs can be used in long - term applications. Unlike pneumatic plugs, which can lose air pressure over time, mechanical plugs do not use air pressure, resulting in a more secure seal.
    • Made of heavy-duty aluminium
    • Neoprene “O” ring (chemical resistant)
    • Sizes 6" - 12" sized for concrete, clay, and SDR 26 & 35 pipe
    • Sizes 15" & 18" sized for concrete & clay pipe sizes only
     

    This product is a special order.  Please contact us for price and availability. 

       
  • Exclusively from Cherne, Multi-Size High Pressure Plugs. Features:
    • Multi range use (6 plugs will cover pipe sizes from 4" to 32")
    • Unlike single sized products, Cherne’s new HP plug has the rubber and metal bonded eliminating fears of separation or rolling off resulting from high backpressures.
    • Aramid fiber construction
    • Optimized design using steel, aramid and natural rubber to ensure longevity and robust construction
    • Cherne recommends using water to inflate these new high pressure plugs
    • Removable and field repairable hardware
    • Safety/Over-inflation device
    • Made in USA
       

    This product is a special order.  Please contact us for price and availability. 

     
     
  • Protective Sleeves Greatly reduces possibility of damage to plug due to debris and sharp objects in the pipe. The protective sleeve also protects plugs when the pipe is degraded. Works particularly well in coastal areas where oysters and barnacles are present. Features:
    • Extends plug life
    • Eliminates superficial cuts on plugs
    • Great for rental distributors & frequent users
    • Maintains back pressure ratings
    • Easy to install without special tools
      Sizes available: 300-600MM i SERIES, 380-800MM, DN600-1200MM,  1200-1800MM, 600-1500MM, 1400-2400MM, 500-1000MM  

    This product is a special order.  Please contact us for price and availability. 

  • Deflection Gauges
    Deflection Gauges (mandrels) are used to test flexible sewer pipe for out-ofroundness or deflection per ASTM specifications D3034 and F679. This testing ensures that flexible pipe has been properly bedded and backfilled (ASTM D2321) to give optimal performance.
    Both steel and aluminum gauges utilize a nine arm design to ensure the pipe is tested accurately. This design also allows gravel and debris to easily pass through.
    Other gauges can get hung up – causing a deflection test to fail, even though the pipe is within tolerance. Sized to .01" , both deflection gauge styles meet ASTM requirements.
    Aluminum Fin Style Deflection Gauge:
    • Lightweight, corrosion-resistant
    • Field-verifiable without a proving ring
    • Assembles without tools
    • All sizes fit through standard 24" manhole
    • Fins for 4"-15" gauges have skid size equal to the nominal pipe size—gauge will meet regional codes and will not tip in the line
    • Nine-fin design ensures testing accuracy
    • Open design allows gravel and debris pass-through
    Fixed Steel Style Deflection Gauge:
    • Durable, zinc-plated construction resists corrosion
    • Conforms to mandrel sizing specifications—blade length is equal to or greater than the nominal pipe size
    • Nine-arm design ensures testing accuracy
    • Open design allows gravel and debris pass-through
    Proving Ring:
    • Used to verify deflection gauge sizes
    • Standard sizes: 6"-15" SDR 35 5% deflection and 8"-12" SDR 35 7.5% deflection
    • Custom sizes for 5"-18" also available
      Sizes available: CUSTOM 5.19 – 6.49", CUSTOM 6.50 – 8.29", CUSTOM 8.30 – 9.99", CUSTOM 10.00 – 12.55", CUSTOM 12.56 – 15.33", CUSTOM 15.34 – 18.99", CUSTOM 19.00 – 20.99", CUSTOM 21.00 – 23.00"  

    This product is a special order.  Please contact us for price and availability. 

  • Smoke Testing Smoke testing sewer systems was introduced in the early 1960’s as a method of identifying areas where extraneous water was entering sanitary sewer systems. Today, smoke testing is known to be a proven method of effectively identifying inflow (storm/ground water entry into sanitary sewer), connected roof and basement drains, yard drains, illegal taps, and storm sewer cross connections. Reducing inflow and infiltration saves costs from treating groundwater at wastewater treatment plants. The Environmental Protection Agency has instructed municipalities to eliminate inflow and infiltration into sewer systems. Smoke testing sewer systems is an effective way to accomplish this goal. Smoke testing is accomplished by isolating a section of sewer line and introducing smoke into the line utilizing a smoke blower and smoke-generating device. (Important: Notify all local authorities and citizens before conducting smoke tests! Cherne provides guidelines for properly preparing and announcing to the community that a smoke test will be conducted.) Lines are first isolated using pipe plugs. Then smoke is introduced into the sewer system. The test crew then checks buildings, roof vents, the street, and other areas that potentially could be a source of extraneous water and records those locations for corrective follow-up. Smoke Blowers Cherne offers the broadest line of smoke testing equipment available today. Our smoke blowers are available for either traditional “smoke bombs” or liquid smoke fluid. Available with Honda or Briggs & Stratton engines, our units generate up to 3,769 cubic feet per minute of airflow to quickly introduce smoke into the sewer system. Cherne’s blowers are made of lightweight cast aluminium and feature a 1/2" foam cell gasket to insure a leak-free seal on manholes and minimize vibration. The traditional smoke blower has a smoke bomb box holder, whereas the liquid smoke blower is supplied with a pressurized tank, hose and all components necessary to conduct the smoke test. Smoke Generating Devices Cherne Smoke Generating Devices (SGD), or “smoke bombs”, produce a thick, dense smoke that is highly effective for performing smoke tests. Smoke generating devices are timeproven, simple to use, and can be used by them selves or with most smoke blowers on the market today. Smoke Fluid Cherne’s Smoke Fluid also produces thick, dense smoke to effectively perform smoke tests. While Smoke Fluid requires some additional equipment to perform a smoke test, municipalities have found smoke fluid to be easy-to-regulate and has virtually an indefinite storage life.  

    This product is a special order.  Please contact us for price and availability. 

     
     
  • Air-Loc® Low Pressure Air-Testing system has been successfully used for pipeline testing for over thirty-five years. This method of testing pipelines has proven to be the fastest, most economical and accurate method for testing pipe. Air-Loc® Line Acceptance Kit. Used to perform a low-pressure air test from manhole to manhole. This is done by installing two Cherne Air-Loc plugs and using Cherne’s Air-Loc Panel to inflate the plugs and pressurise the pipeline. The test pressure is monitored for a predetermined amount of time for any decrease in pressure. If pressure drops less than 1 psi, the test passes. If a leak is detected, additional equipment is required to isolate the leak.  

    This product is available by special order. Please note that the pump is not included but can be purchased separately. For pricing and availability, please contact us.

  • Air-Loc® Leak Location Kit. If the line acceptance test indicates a leak in the sewer line, it becomes necessary to locate the leak(s) so that proper repairs can be made. A leak location (segment) test is accomplished by first stringing the sewer line using a Cherne Air-Loc Line Stringer or float line. Once strung, a winch cable is used to pull two Air-Loc Leak Locator plugs, which are attached together with an interconnect hose, through the pipeline in 22' intervals. Air is introduced between the plugs at each 22' increment until the test fails. Then, by moving the plugs back and forth, the leak can be isolated within two feet.  

    This product is a special order.  Please contact us for price and availability. 

  • The versatile Air-Loc® Fan Assembly can be used as a line stringer and smoke blower. Made from lightweight cast aluminium, this assembly includes a 5HP Honda or Briggs & Stratton engine and top mounted handles for easy manoeuvrability. Air-Loc® Fan Assembly Features:
    • For use as a line stringer andsmoke blower
    • Made of lightweight, cast aluminum
    • Foam base minimizes vibration
    • 30" Diameter base plate
    Equipped with:
    • Honda or Briggs & Stratton engine
    • Top-mounted handles for easy maneuverability
    Line Stringer Usage Details:
    • Will string a 300' section of sewer line in under a minute without plugging the line
    • Line stringer vacuum pulls a lightweight nylonparachute through wet or dry lines
      Available Engine Types: FAN ASSEMBLY AIR-LOC (B&S ENGINE) L/STRI FAN ASSEMBLY AIR-LOC (HONDA ENGINE)  

    This product is a special order.  Please contact us for price and availability. 

  • Positioned usually by a crawler and expanded pneumatically, Quick-Lock’s rehab sleeve provides structural, trenchless pipe repair with heavy-gauge 316 stainless steel, plus infiltration abatement with an EPDM rubber gasket. Quick-Lock is the solution for:
    • Infiltration.
    • Longitudinal cracks.
    • Circumferential cracks.
    • Holes.
    • Separated joints.
    • Offset joints.
    • Abandoned laterals.
    • Root intrusion.
    • Quick-Lock sleeves in the smaller range are available in diameters ranging DN100–DN825, and in lengths of 400mm, and 500mm.
    • DN825-DN1800 pipes are also catered for under confined space entry with the Quick-Lock Big seal.
    • Multiple sleeves can be interleaved to perform longer repairs (JDL's) and for radial displacements (JDR's) choose the new Quick-Lock Flex seal.
     
  • The Quick-Lock BIG sleeve is a product for permanently and tightly sealing leaking pipe joints, radial cracks, and longitudinal cracks in large pipes and manholes of DN 800 and larger.
    • The sleeve is 20 cm wide.
    • The sealed area (between the circumferential seals) is approximately 12 cm.
      (The distance between the circumferential seals is approximately 14 cm. However, these are pulled together when the jacket is expanded so that the sealed area is 12 cm wide.) The system is made from V4A stainless steel of grade 1.4404 (AISI 316L) and an EPDM compression seal.
    • The materials used are permanently resistant in municipal wastewater systems.
    • Their suitability must be ascertained for use in industrial or polluted wastewater.
  • Air-Loc® Manhole Testers provide the most efficient, accurate, and cost effective method of testing new, existing, and rehabilitated manholes. Vacuum testing identifies infiltration and exfiltration problems.  

    This product is a special order.  Please contact us for price and availability. Vacuum pump not included.

Go to Top