- Allows operator to push, turn or pull. Coupling is locked with a pin.
- Out of stockTEMPORARILY OUT OF STOCK Cherne Smoke Generating Devices (SGD), or “smoke bombs”, produce a thick, dense smoke that is highly effective for performing smoke tests. Smoke generating devices are time proven, simple to use, and can be used by themselves or with most smoke blowers on the market today. Features:
- Produces a thick, dense smoke
- Time-proven
- Simple to use
- Can be used with most smoke blowers
- 3 minute bombs available with a double wick that allows units to be strung together for a longer smoke time
- Method for the Sectional Renovation of Lateral Junctions and Pipes in the Main Sewer Line Main pipe: DN 130 to DN 600 Lateral pipe: DN 100, 125, 150 and 200 at 30° to 90° The DrainLCR-S system is used to repair and permanently seal main/lateral interfaces and connections up to 500 mm from the mainline down into the lateral. The system can use either an LCR-S hat profile or an LCR-S liner. The main-to-lateral interface in the main pipe is sealed only by the rim of the LCR-S hat profile, while the LCR-S liner in the main pipe is designed as a short liner. Benefits:
- Reliable to install: 1. Inversion is not possible until positive engagement of the pathfinder. 2. The signal will not sound until complete inversion.
- Technical advance: Only the inversion process allows pipe bends and offset joints to be relined.
- Meets practical needs: Successful repairs are possible with little equipment needs only, even in the presence of groundwater.
- Price advantage: Low investment cost, because you need to buy just the packers actually required.
- Practical: The low-weight mobile unit with low space requirements can be placed even in a small car.
- Flexible: It is also possible to use air push rods or a carriage.
- Accessibility: The LCR packers can be folded as required inside the manhole.
- User-friendly equipment: The LCR packers can be converted to other sizes as required.
- Used for assembly and disassembly of the rod couplings and nuts. The end of the handle is designed to fit the center hole of the coupling. 2 are recommended.
- Hydrostatic Test Pumps are designed for pressure testing water lines and sewer force mains as prescribed by AWWA Standard C600 Installation of Ductile-Iron Water Mains and C605 Installation of PVC Pressure Pipe. Aqua-Loc® Hydrostatic Test Pumps are designed to be the most user friendly in the industry. Both Diaphragm and Piston Style pumps are available and come powered by either a Honda or Briggs & Stratton engine. Aqua-Loc® Hydrostatic Test Pump: Diaphragm Style – Features:
- Honda or Briggs Engine with low oil shut off
- Hypro® Twin diaphragm pump - 9.5 gpm/550 PSI
- Handles up to 10% chlorine solutions
- May be run dry
- Test pressures can be set from 100-550 psi
- Integral manifolds - eliminates leak points
- Enclosed gear reduction - excellent heat dissipation
- Pulsation dampener - no need to surge tank
- Heavy-duty frame
- Hydraulic quick-disconnect - brass, swivel fitting
- Inline strainer - easy to clean clear bowl
- Clear hose - flow verification
- Silicone filled test gauge w/stainless steel case
- A lightweight aluminum pole system which is used to place the Remo® plug in the sewer system. For longer then 1.8m use two poles with the Remo® Pole Adapter.
- Universal model with rectangular base ideal for lifting, moving and repositioning the majority of covers and grilles in cast iron and ferrous materials. The handle is telescopic and folding, minimising the space needed. The exclusive configuration gives versatility of use in four ways to fit the majority of lifting/repositioning operations. The plate, with 16 powerful neodymium magnets assures a lifting force of 300kg with a weight of only 7kg.
- Designed to penetrate the toughest blockages the enz® pointed nozzle directs 30% of your jetters flow forward 15º through its hardened tip to break up and open the blockage. The remainder is exhausted at a 20º angle to provide positive thrust and penetrating power. Ideal for roots, silt, heavily blocked pipes and frozen pipes. L= Litres per minute R= Number of Rear Facing Jets F= Number of Front Facing Jets If a nozzle you require is not listed please call or enquire online for price & availability.
- Out of stockDesigned to penetrate the toughest blockages the enz® pointed nozzle directs 30% of your jetters flow forward 15º through its hardened tip to break up and open the blockage. The remainder is exhausted at a 20º angle to provide positive thrust and penetrating power. Ideal for roots, silt, heavily blocked pipes and frozen pipes. L= Litres per minute R= Number of Rear Facing Jets F= Number of Front Facing Jets If a nozzle you require is not listed please call or enquire online for price & availability.
- Our new Super Heavy Duty Puma Tail hose guide is molded from a smooth bore rubber hose that holds up to abuse. These Puma Tails last longer to keep your workers on the job and avoid costly sewer hose damage. The cuffed ends are steel banded and silicone sealed. The attached 25ft. rope is attached with a super strong King Clamp with a rubber gasket around the guide. Sizes available: 2" Heavy Duty Tiger Tail Puma Hose Guide & 3" Heavy Duty Tiger Tail Puma Hose Guide Please contact us for price & availability.
- 45KGS Capacity. An overall metal retriever. Connects right to our fiberglass poles. Great tool for retrieving that lost tool; can lift valve covers. Comes with steel protective plate to protect magnet. Zinc plated.